The XK W2001 temperature controller module is used to delay the operation of the device after the power is cut off and restored to protect the load such as refrigerator or freezer from damage. It operates at a voltage of 220V and a current of 6A (1500W). It controls temperatures between -50°C and 110°C, and also has the ability to control heating or cooling.
How to use:
P0 to set the start temperature:
Press the set button to enter the internal menu, the default display is P0. Press the set button again to set the desired start temperature by pressing the up and down buttons.
P1 to set the stop temperature:
Press the set button to enter the internal menu, the digital display is P0, press the up and down buttons to go to P1, press the set button again, and press the up and down buttons to set the desired stop temperature.
P2 for temperature correction:
Enter the internal menu in the same way, use the up and down buttons to go to P2, press the set button again, and use the up and down buttons to set the desired calibration temperature. In the settings, if the detected temperature value is 0.5 ° C higher than the actual temperature value, the desired calibration temperature is set to -0.5 ° C. If the detected temperature value is 1 ° C lower than the actual temperature value, the set calibration temperature is 1 ° C. Detected temperature ± calibration temperature = actual temperature.
Setting P3 start delay:
Enter the internal menu in the same way, use the up and down buttons to go to P3, press the set button again, and use the up and down buttons to set the desired delay time (in minutes). Delayed start is usually used to cool the compressor, if it is used for refrigerators, this value needs to be set, depending on the size of the compressor back pressure, the general setting value is 3-6 minutes, if you are not used to controlling the compressor or do not need the delay function, directly ignore this
Heating mode setting method:
Setting key: Start temperature < Stop temperature (the program automatically sets the working mode as heating mode)
Cooling mode setting method:
Setting key: Start temperature > Stop temperature (the program automatically sets the working mode as cooling mode)
Note:
When setting the heating mode, if the set temperature value is accidentally reversed, the output indicator will not light up and the load will not work, if the above situation occurs after setting, you can check whether the set temperature value is reversed.
It has a standard power socket on the body, which can be directly connected to various devices, and also supports a maximum output of 6A and 1500W. Depending on the temperature settings, the socket automatically turns the power on or off.