Your shopping cart is empty!
0 reviews / Write a review
Tags: Smoke Detector, Gas Sensor, Smoke Sensor, Ionization Sensor, Gas Detector
Descriptions:The unit chamber structure designed according to the best performance of computer simulation, this ionization chamber is dedicated to smoke detectors. All materials are made of highly corrosion-resistant materials, and the safety performance reaches BS/ISO/ANS/GB C64646 standards.NIS - 07 ion smoke sensors have an ionization chamber, the ion chamber used artificial radioactive element americium 241 (Am241), the intensity of about 0.8 micro Curie, under the normal state is in the balance of the electric field condition, when there is a smoke into the ionization chamber, ionization produced positive and negative ions, interfere with the normal movement of the charged particle, under the action of electric field, respectively to the positive and negative electrode, destroyed the balance between the internal and external ionization chamber, current, the voltage will change. Ion smoke smoke sensor is through the equivalent resistor voltage changes due to ionization chamber to perceive micro electric current change device of smoke particles. To macro performance for the equivalent resistance of ionization chamber increase causes the voltage at the ends of the ionization chamber, thus to determine the status of the smoke in the air.Within the ionization chamber, there are two plates with voltage in between them. If an electron in this space is knocked out of place due to smoke entering the chamber, it causes ionization, and, in response, the fire alarm goes off.
Ionization source characteristics and radiation safety performance:The ionization chamber fitted with a high performance and low activity of Am-241 ionizationIonization source activity: 0.5uCi ( 18KBq ) 0.8uCi±10% ( 30KBq±10% )Ionization source a spectroscopy: peak: 4.5MeV ± 10%, FW HM<0.7MeVSafety grading standards ( GB4075, IS02919 ) C64444Ionization chamber radiation dose rate at 25cm: 0.03mGy/ (1mGy value lower than population does standard)
Features:Outer electrode and the source electrode voltage ( VDD supply voltage ): 9VOperating Temperature: 20 ± 3℃ close to atmospheric pressure standard atmospheric pressure, clean airCollecting electrode equilibrium potential: 5.3V ~ 6.5VCollecting electrode potential with the smoke concentration changeThe light reduction rate was 1% feet: 0.6VThe light reduction rate was 4% feet: 2.2VInsulator leakage current ( Max. ): 0.5PaCapacitor ( collection of extreme outer electrode + to the source base ): 6pFMaterial: MetalColor: SilverSize: 28mm x 16mm x 37mm
Package Include:1 x ION Chamber Smoke Detector Sensor
Your B2B Supplying Partner in Mainland China
Using Vast Majority of International Couriers
Always Pay with Trust by PayPal Express Checkout